📞 +91 98200 30685✉️
RERA: A51800043517

Fortuna Blue

by Alliance Infracorp Developers Partnership
Certificate SignedP51900018299

Project Information

RERA Certificate No.
P51900018299
Registration No.
REA51900045378
Registration Date
2022-05-25
Developer
Alliance Infracorp Developers Partnership
Architect
Bn Shah & Associates
Project Bank
KOTAK MAHINDRA BANK LIMITED
Proposed Possession
2025-12-31
Revised Possession
1900-01-01
Extended Possession
1900-01-01
Total Units
101
Units Sold
99 (98%)
Buildings
2
Project Area
2172.25 sq.m
Total FSI
11959.42
Approved FSI
11959.42
MahaRERA QR
Fortuna Blue
MahaRERA — P51900018299
Scan to verify on MahaRERA portal

Wing-wise Details

🏗️Proposed Floors26
Sanctioned26
🏠Habitable20
🔢Total Units9
🏡Residential9
📅Completion2025-03-31
🏗️Proposed Floors26
Sanctioned26
🏠Habitable20
🔢Total Units92
🏡Residential90
🏢Non-Residential2
🚗Open Parking6
🅿️Closed Parking64
📅Completion2025-12-31

Apartment Configurations

None

TypeCarpet (sq.ft)TotalBookedAvailableStatus
1Bhk38.150001525878906000
0%
1Bhk39.13999938964844000
0%
1Bhk40.189998626708984000
0%
1Bhk42.47999954223633000
0%
1Bhk46.38999938964844000
0%
1Bhk49.810001373291016000
0%
1Bhk53.0000
0%
1Bhk53.91999816894531000
0%
2Bhk60.13999938964844000
0%
2Bhk69.62999725341797000
0%
Room11.520000457763672000
0%
Room22.329999923706055000
0%

Wing -A

TypeCarpet (sq.ft)TotalBookedAvailableStatus
1 BHK38.15220
100%
1 BHK39.14110
100%
1 BHK40.19330
100%
1 BHK53.0101
0%
1 BHK53.92202
0%

Wing-B

TypeCarpet (sq.ft)TotalBookedAvailableStatus
1 BHK42.4817143
82%
1 BHK46.3917116
65%
1 BHK49.8117143
82%
2 BHK60.14101
0%
2 BHK69.6338317
82%
Room11.52110
100%
Room22.33110
100%

Construction Progress

Wing -A

Basement (if any)100%
Excavation100%
External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.100%
Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate75%
Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.100%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises100%
Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises95%
Plinth100%
Podiums (if any) 100%
Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises90%
Sanitary Fittings within the flats / premises100%
Slabs of Super Structure100%
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.90%
Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks100%
Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing95%
X number of Basement(s) and Plinth100%
X number of Podiums100%
X number of Slabs of Super Structure100%

Wing-B

Basement (if any)100%
Excavation100%
External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.100%
Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate80%
Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.100%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises100%
Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises100%
Overall Percentage of Completion of the work done For the entire Building /Wing95%
Plinth100%
Podiums (if any) 100%
Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises90%
Sanitary Fittings within the flats / premises100%
Slabs of Super Structure100%
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.90%
Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks100%
Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing100%
X number of Basement(s) and Plinth100%
X number of Podiums100%
X number of Slabs of Super Structure100%

RERA Registered Amenities

Aggregate area of recreational Open Space
Community Buildings
Electrical Meter Room, Sub-Station, Receiving Station80%
Energy management
Fire Protection And Fire Safety Requirements75%
Landscaping & Tree Planting
Open Parking
Sewerage (Chamber, Lines, Septic Tank , STP)60%
Solid Waste Management And Disposal
Storm Water Drains40%
Street Lighting
Treatment And Disposal Of Sewage And Sullage Water
Water Conservation, Rain water Harvesting
Water Supply50%
CallWhatsApp
✉️

Get in Touch

Our team will connect with you shortly

+91
🔒 Your details are secure with us
⚡ If need urgent details +91 98200 67525 for further details.
This website is for the use of Actual Home Buyers/Renters and Owners and Property Investors only.