📞 +91 98200 30685 ✉️
RERA: A51800043517

PARANJAPE ATHENA

by PARANJAPE SPACES AND SERVICES PVT LTD Company
Certificate Signed P51800049529
💬 WhatsApp 📞 Call

Project Information

RERA Certificate No.
P51800049529
Registration No.
REA51800129363
Registration Date
2023-02-15
Developer
PARANJAPE SPACES AND SERVICES PVT LTD Company
Project Bank
KOTAK MAHINDRA BANK LIMITED
Proposed Possession
2027-12-31
Revised Possession
1900-01-01
Extended Possession
1900-01-01
Units Sold
0
Buildings
5
Project Area
3509.30 sq.m
Total FSI
14208.81
Approved FSI
9607.60
MahaRERA QR
PARANJAPE ATHENA
MahaRERA — P51800049529
Scan to verify on MahaRERA portal

Wing-wise Details

🏗️Proposed Floors11
Sanctioned11
⬇️Basements1
📅Completion2027-12-31
🏗️Proposed Floors17
Sanctioned17
⬇️Basements1
📅Completion2027-12-31
🏗️Proposed Floors17
Sanctioned17
⬇️Basements1
📅Completion2027-12-31
🏗️Proposed Floors12
Sanctioned12
⬇️Basements1
📅Completion2027-12-31
🏗️Proposed Floors11
Sanctioned11
⬇️Basements1
📅Completion2027-12-31

Apartment Configurations

Paranjape Athena D Wing

Type Carpet (sq.ft) Total Booked Available Status
1 BHK 41.49 13 0 13
0%
2 BHK 58.59 12 1 11
8%
2 BHK 61.97 12 1 11
8%
3 BHK 79.23 1 0 1
0%
3 BHK 83.38 1 0 1
0%

Paranjape Athena Wing A

Type Carpet (sq.ft) Total Booked Available Status
0 0 0
0%

Paranjape Athena Wing B

Type Carpet (sq.ft) Total Booked Available Status
0 0 0
0%

Paranjape Athena Wing C

Type Carpet (sq.ft) Total Booked Available Status
1 BHK 44.16 13 1 12
8%
2 BHK 57.27 13 1 12
8%
2 BHK 58.3 14 0 14
0%
2 BHK 63.88 13 0 13
0%

Paranjape Athena Wing E

Type Carpet (sq.ft) Total Booked Available Status
2 BHK 59.35 14 0 14
0%
3 BHK 79.35 14 0 14
0%
3 BHK 83.01 13 2 11
15%

Construction Progress

PARANJAPE ATHENA D WING

Basement (if any)100%

Paranjape Athena D Wing

Excavation100%

PARANJAPE ATHENA D WING

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.20%

Paranjape Athena D Wing

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%

PARANJAPE ATHENA D WING

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises10%

Paranjape Athena D Wing

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises5%

PARANJAPE ATHENA D WING

Plinth100%
Podiums (if any) 0%

Paranjape Athena D Wing

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises2%

PARANJAPE ATHENA D WING

Sanitary Fittings within the flats / premises2%
Slabs of Super Structure93%

Paranjape Athena D Wing

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.0%

PARANJAPE ATHENA D WING

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks0%

Paranjape Athena D Wing

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure40%

PARANJAPE ATHENA WING A

Basement (if any)100%

Paranjape Athena Wing A

Excavation100%

PARANJAPE ATHENA WING A

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.25%

Paranjape Athena Wing A

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%

PARANJAPE ATHENA WING A

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises0%

Paranjape Athena Wing A

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises10%

PARANJAPE ATHENA WING A

Plinth100%
Podiums (if any) 0%

Paranjape Athena Wing A

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises2%

PARANJAPE ATHENA WING A

Sanitary Fittings within the flats / premises2%
Slabs of Super Structure100%

Paranjape Athena Wing A

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.0%

PARANJAPE ATHENA WING A

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks0%

Paranjape Athena Wing A

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure65%

PARANJAPE ATHENA WING B

Basement (if any)100%

Paranjape Athena Wing B

Excavation100%

PARANJAPE ATHENA WING B

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.25%

Paranjape Athena Wing B

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%

PARANJAPE ATHENA WING B

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises0%

Paranjape Athena Wing B

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises10%

PARANJAPE ATHENA WING B

Plinth100%
Podiums (if any) 0%

Paranjape Athena Wing B

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%

PARANJAPE ATHENA WING B

Sanitary Fittings within the flats / premises0%
Slabs of Super Structure100%

Paranjape Athena Wing B

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.0%

PARANJAPE ATHENA WING B

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks0%

Paranjape Athena Wing B

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure65%

PARANJAPE ATHENA WING C

Basement (if any)100%

Paranjape Athena Wing C

Excavation100%

PARANJAPE ATHENA WING C

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.20%

Paranjape Athena Wing C

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%

PARANJAPE ATHENA WING C

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises10%

Paranjape Athena Wing C

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises10%

PARANJAPE ATHENA WING C

Plinth100%
Podiums (if any) 0%

Paranjape Athena Wing C

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%

PARANJAPE ATHENA WING C

Sanitary Fittings within the flats / premises0%
Slabs of Super Structure100%

Paranjape Athena Wing C

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.0%

PARANJAPE ATHENA WING C

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks0%

Paranjape Athena Wing C

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure65%

PARANJAPE ATHENA WING E

Basement (if any)100%

Paranjape Athena Wing E

Excavation100%

PARANJAPE ATHENA WING E

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.15%

Paranjape Athena Wing E

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%

PARANJAPE ATHENA WING E

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises10%

Paranjape Athena Wing E

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises5%

PARANJAPE ATHENA WING E

Plinth100%
Podiums (if any) 0%

Paranjape Athena Wing E

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%

PARANJAPE ATHENA WING E

Sanitary Fittings within the flats / premises0%
Slabs of Super Structure93%

Paranjape Athena Wing E

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.0%

PARANJAPE ATHENA WING E

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks0%

Paranjape Athena Wing E

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure40%

RERA Registered Amenities

Aggregate area of recreational Open Space
Community Buildings
DG Back Up
Electrical Meter Room, Sub-Station, Receiving Station
Energy management
Fire Protection And Fire Safety Requirements
Fitness Centre
Landscaping & Tree Planting
Open Parking
Sewerage (Chamber, Lines, Septic Tank , STP)
Solid Waste Management And Disposal
Storm Water Drains
Street Lighting
Treatment And Disposal Of Sewage And Sullage Water
Water Conservation, Rain water Harvesting
Water Supply
Call WhatsApp
✉️

Get in Touch

Our team will connect with you shortly

+91
🔒 Your details are secure with us
⚡ If need urgent details +91 98200 67525 for further details.
This website is for the use of Actual Home Buyers/Renters and Owners and Property Investors only.