📞 +91 98200 30685 ✉️
RERA: A51800043517

Rustomjee Virar Avenue L1-L2 and L4 Wing I J and Retail

by KEYSTONE INFRASTRUCTURE PRIVATE LIMITED Company
Certificate Signed P99000020216
💬 WhatsApp 📞 Call

Project Information

RERA Certificate No.
P99000020216
Registration No.
REA99000054566
Registration Date
2021-09-09
Developer
KEYSTONE INFRASTRUCTURE PRIVATE LIMITED Company
Architect
M/S. Abhikalpan Architects & Planners
Project Bank
ICICI BANK LIMITED
Proposed Possession
2023-09-30
Revised Possession
1900-01-01
Extended Possession
2025-12-31
Units Sold
0
Buildings
3
Project Area
1318.56 sq.m
Total FSI
10383.18
Approved FSI
10383.18
MahaRERA QR
Rustomjee Virar Avenue L1-L2 and L4 Wing I J and Retail
MahaRERA — P99000020216
Scan to verify on MahaRERA portal

Wing-wise Details

🏗️Proposed Floors4
Sanctioned4
🚗Open Parking7
📅Completion2023-03-30
🏗️Proposed Floors18
Sanctioned18
🚗Open Parking4
🅿️Closed Parking44
📅Completion2023-03-30
🏗️Proposed Floors18
Sanctioned18
🚗Open Parking4
🅿️Closed Parking44
📅Completion2023-03-30

Apartment Configurations

None

Type Carpet (sq.ft) Total Booked Available Status
1 Bhk Type 1 30.739999771118164 0 0 0
0%
1Bhk Type 1 30.739999771118164 0 0 0
0%
2Bhk Type 1 43.869998931884766 0 0 0
0%
2Bhk Type 2 47.56999969482422 0 0 0
0%
Unit 1 160.1300048828125 0 0 0
0%
Unit 2 164.33999633789062 0 0 0
0%

Retail

Type Carpet (sq.ft) Total Booked Available Status
unit 1 160.13 1 0 1
0%
unit 2 164.34 3 0 3
0%

Wing I

Type Carpet (sq.ft) Total Booked Available Status
1 BHK type 1 30.74 59 56 3
95%
2 BHK type 1 43.87 28 27 1
96%
2 BHK type 2 47.57 30 27 3
90%

Wing J

Type Carpet (sq.ft) Total Booked Available Status
1 BHK type 1 30.74 59 57 2
97%
2 BHK type 1 43.87 28 25 3
89%
2 BHK type 2 47.57 30 25 5
83%

Construction Progress

Retail

Basement (if any)0%
Excavation0%
External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.0%
Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%
Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises0%
Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises0%
Overall Percentage of Completion of the work done For the entire Building /Wing0%
Plinth0%
Podiums (if any) 0%
Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%
Sanitary Fittings within the flats / premises0%
Slabs of Super Structure0%
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.0%
Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks0%
Stilt Floor0%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth0%
X number of Podiums0%
X number of Slabs of Super Structure0%

Wing I

Basement (if any)100%
Excavation100%
External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.80%
Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate50%
Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.50%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises90%
Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises90%
Overall Percentage of Completion of the work done For the entire Building /Wing61%
Plinth100%
Podiums (if any) 0%
Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%
Sanitary Fittings within the flats / premises0%
Slabs of Super Structure100%
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.90%
Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks90%
Stilt Floor0%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing80%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure100%

Wing J

Basement (if any)100%
Excavation100%
External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.60%
Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate50%
Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.50%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises40%
Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises40%
Overall Percentage of Completion of the work done For the entire Building /Wing51%
Plinth100%
Podiums (if any) 0%
Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%
Sanitary Fittings within the flats / premises0%
Slabs of Super Structure100%
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.60%
Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks60%
Stilt Floor0%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing60%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure100%

RERA Registered Amenities

Aggregate area of recreational Open Space
box cricket on podium top
common area fire sprinklers
common area lighting
Community Buildings
Designer Entrance Lobby
DG Back up for Elevators and Common area Lighting
Earthquake resistant structure
Electrical Meter Room, Sub-Station, Receiving Station
Elevators
Energy management
Fire Protection And Fire Safety Requirements
futsal court on podium top
Landscaping & Tree Planting
multipurpose lawn on podium top
Open Parking
Organic Waste converter for recycle of wet garbage
podium top landscaping and trees planting
Sewerage (Chamber, Lines, Septic Tank , STP)
skating area on podium top
Solar System
Solid Waste Management And Disposal
Staircase and lift lobbies
Storm Water Drains
Street Lighting
Treatment And Disposal Of Sewage And Sullage Water
walking cum jogging track on podium top
Water Conservation, Rain water Harvesting
Water Supply
Call WhatsApp
✉️

Get in Touch

Our team will connect with you shortly

+91
🔒 Your details are secure with us
⚡ If need urgent details +91 98200 67525 for further details.
This website is for the use of Actual Home Buyers/Renters and Owners and Property Investors only.