📞 +91 98200 30685 ✉️
RERA: A51800043517

POONAM IMPERIA PHASE I

by POONAM SKYLINE CONSTRUCTION Partnership
Certificate Signed P99000017908
💬 WhatsApp 📞 Call

Project Information

RERA Certificate No.
P99000017908
Registration No.
REA99000044439
Registration Date
2023-02-14
Developer
POONAM SKYLINE CONSTRUCTION Partnership
Architect
Encon Architectural & Structural Works Project Consultants
Project Bank
HDFC BANK
Proposed Possession
2022-11-30
Revised Possession
1900-01-01
Extended Possession
2025-01-31
Units Sold
0
Buildings
4
Project Area
5273.71 sq.m
Total FSI
13216.00
Approved FSI
13216.00
MahaRERA QR
POONAM IMPERIA PHASE I
MahaRERA — P99000017908
Scan to verify on MahaRERA portal

Wing-wise Details

🏗️Proposed Floors15
Sanctioned15
🅿️Closed Parking44
📅Completion2022-05-31
🏗️Proposed Floors15
Sanctioned15
🅿️Closed Parking53
📅Completion2022-05-31
🏗️Proposed Floors15
Sanctioned15
🅿️Closed Parking45
📅Completion2022-05-31
🏗️Proposed Floors8
Sanctioned8
🚗Open Parking23
🅿️Closed Parking1
📅Completion2022-05-31

Apartment Configurations

None

Type Carpet (sq.ft) Total Booked Available Status
1 Bhk 32.810001373291016 0 0 0
0%
1Bhk 22.809999465942383 0 0 0
0%
1Bhk 30.979999542236328 0 0 0
0%
1Bhk 31.280000686645508 0 0 0
0%
1Bhk 31.959999084472656 0 0 0
0%
1Bhk 32.810001373291016 0 0 0
0%
1Bhk 32.900001525878906 0 0 0
0%
1Bhk 33.22999954223633 0 0 0
0%
1Bhk 33.310001373291016 0 0 0
0%
1Bhk 33.349998474121094 0 0 0
0%
1Bhk 33.90999984741211 0 0 0
0%
1Bhk 34.619998931884766 0 0 0
0%
2Bhk 40.11000061035156 0 0 0
0%
2Bhk 40.72999954223633 0 0 0
0%
2Bhk 40.869998931884766 0 0 0
0%
2Bhk 41.0 0 0 0
0%
2Bhk 41.13999938964844 0 0 0
0%
2Bhk 42.279998779296875 0 0 0
0%

A Wing

Type Carpet (sq.ft) Total Booked Available Status
1 BHK 32.81 26 2 24
8%
1 BHK 33.23 28 6 22
21%
2 BHK 41.0 28 4 24
14%
2 BHK 41.14 28 6 22
21%

B Wing

Type Carpet (sq.ft) Total Booked Available Status
1 BHK 32.81 26 15 11
58%
1 BHK 33.23 14 10 4
71%
1 BHK 33.31 14 13 1
93%
2 BHK 40.73 14 14 0
100%
2 BHK 40.87 28 26 2
93%

C Wing

Type Carpet (sq.ft) Total Booked Available Status
1 BHK 32.9 13 8 5
62%
1 BHK 33.31 13 7 6
54%
2 BHK 40.11 56 55 1
98%

H Wing

Type Carpet (sq.ft) Total Booked Available Status
1 BHK 22.81 1 1 0
100%
1 BHK 30.98 7 4 3
57%
1 BHK 31.28 6 4 2
67%
1 BHK 31.96 7 6 1
86%
1 BHK 33.35 5 4 1
80%
1 BHK 33.91 7 5 2
71%
1 BHK 34.62 7 2 5
29%
2 BHK 42.28 1 1 0
100%

Construction Progress

A WING

Basement (if any)100%

A Wing

Excavation100%

A WING

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.100%

A Wing

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate50%

A WING

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.100%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises100%

A Wing

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises80%
Overall Percentage of Completion of the work done For the entire Building /Wing72%

A WING

Plinth100%
Podiums (if any) 0%

A Wing

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%

A WING

Sanitary Fittings within the flats / premises100%
Slabs of Super Structure100%

A Wing

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.100%

A WING

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks100%

A Wing

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing90%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure100%

B WING

Basement (if any)100%

B Wing

Excavation100%

B WING

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.100%

B Wing

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate100%

B WING

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.100%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises100%

B Wing

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises100%
Overall Percentage of Completion of the work done For the entire Building /Wing89%

B WING

Plinth100%
Podiums (if any) 0%

B Wing

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises90%

B WING

Sanitary Fittings within the flats / premises90%
Slabs of Super Structure100%

B Wing

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.100%

B WING

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks100%

B Wing

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing100%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure100%

C WING

Basement (if any)100%

C Wing

Excavation100%

C WING

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.100%

C Wing

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate100%

C WING

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.100%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises100%

C Wing

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises100%
Overall Percentage of Completion of the work done For the entire Building /Wing89%

C WING

Plinth100%
Podiums (if any) 0%

C Wing

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises90%

C WING

Sanitary Fittings within the flats / premises90%
Slabs of Super Structure100%

C Wing

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.100%

C WING

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks100%

C Wing

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing100%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure100%

H WING

Basement (if any)100%

H Wing

Excavation100%

H WING

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.100%

H Wing

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate100%

H WING

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.100%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises100%

H Wing

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises100%
Overall Percentage of Completion of the work done For the entire Building /Wing89%

H WING

Plinth100%
Podiums (if any) 0%

H Wing

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises90%

H WING

Sanitary Fittings within the flats / premises90%
Slabs of Super Structure100%

H Wing

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.100%

H WING

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks100%

H Wing

Stilt Floor100%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing100%
X number of Basement(s) and Plinth100%
X number of Podiums0%
X number of Slabs of Super Structure100%

RERA Registered Amenities

Aggregate area of recreational Open Space
Community Buildings
Electrical Meter Room, Sub-Station, Receiving Station 50%
Energy management
Fire Protection And Fire Safety Requirements 50%
Landscaping & Tree Planting 80%
Open Parking
Sewerage (Chamber, Lines, Septic Tank , STP) 80%
Solid Waste Management And Disposal
Storm Water Drains
Street Lighting
Treatment And Disposal Of Sewage And Sullage Water
Water Conservation, Rain water Harvesting
Water Supply 90%
Call WhatsApp
✉️

Get in Touch

Our team will connect with you shortly

+91
🔒 Your details are secure with us
⚡ If need urgent details +91 98200 67525 for further details.
This website is for the use of Actual Home Buyers/Renters and Owners and Property Investors only.