📞 +91 98200 30685✉️
RERA: A51800043517

Shreeji Eternity Wing - A, Shreeji Eternity Wing - B, Shreeji Eternity Wing - C

by Shreeji Construction Partnership
Certificate SignedP51800054310

Project Information

RERA Certificate No.
P51800054310
Registration No.
REA51800150029
Registration Date
2024-01-15
Developer
Shreeji Construction Partnership
Project Bank
HDFC BANK
Proposed Possession
2027-06-30
Revised Possession
1900-01-01
Extended Possession
1900-01-01
Total Units
197
Units Sold
79 (40%)
Buildings
3
Project Area
3467.63 sq.m
Total FSI
13644.57
Approved FSI
11929.87
MahaRERA QR
Shreeji Eternity Wing - A, Shreeji Eternity Wing - B, Shreeji Eternity Wing - C
MahaRERA — P51800054310
Scan to verify on MahaRERA portal

Wing-wise Details

🏗️Proposed Floors17
Sanctioned17
🅿️Closed Parking41
📅Completion2027-06-30
🏗️Proposed Floors19
Sanctioned19
🅿️Closed Parking51
📅Completion2027-06-30
🏗️Proposed Floors19
Sanctioned19
🅿️Closed Parking1
📅Completion2027-06-30

Apartment Configurations

A Wing

TypeCarpet (sq.ft)TotalBookedAvailableStatus
2 BHK29.73101
0%
2 BHK44.41101
0%
2 BHK50.1730030
0%
2 BHK63.6410010
0%
Shop30.47202
0%
Shop52.03101
0%
Shop89.74202
0%
Shop101.26101
0%
Shop276.29101
0%

B Wing

TypeCarpet (sq.ft)TotalBookedAvailableStatus
2 BHK28.43101
0%
2 BHK31.22101
0%
2 BHK35.86101
0%
2 BHK43.01101
0%
2 BHK47.66101
0%
2 BHK50.1733033
0%
2 BHK59.4612012
0%
Shop77.29101
0%
Shop84.54101
0%
Shop101.45101
0%
Shop103.49202
0%
Shop285.77202
0%

C Wing

TypeCarpet (sq.ft)TotalBookedAvailableStatus
2 BHK43.48101
0%
2 BHK50.1735035
0%
2 BHK54.44404
0%
2 BHK63.6410010
0%
Shop33.17101
0%
Shop41.62202
0%
Shop41.71101
0%
Shop100.33202
0%
Shop374.67101
0%

Construction Progress

A wing

Basement (if any)100%

A Wing

Excavation100%

A wing

External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.0%

A Wing

Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%

A wing

Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises5%

A Wing

Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises0%

A wing

Plinth100%
Podiums (if any) 66%

A Wing

Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%

A wing

Sanitary Fittings within the flats / premises0%
Slabs of Super Structure0%

A Wing

Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.22%

A wing

Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks24%

A Wing

Stilt Floor0%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth100%
X number of Podiums11%
X number of Slabs of Super Structure0%

B Wing

Basement (if any)100%
Excavation100%
External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.0%
Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%
Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises5%
Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises0%
Plinth100%
Podiums (if any) 66%
Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%
Sanitary Fittings within the flats / premises0%
Slabs of Super Structure0%
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.22%
Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks24%
Stilt Floor0%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth100%
X number of Podiums11%
X number of Slabs of Super Structure0%

C Wing

Basement (if any)100%
Excavation100%
External plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building / wing.0%
Installation of lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings to Common Areas, electro, mechanical equipment, Compliance to conditions of environment /CRZ NOC, Finishing to entrance lobby/s, plinth protection, paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to Obtain Occupation /Completion Certificate0%
Installation of Lifts, water pumps, Fire Fighting Fittings and Equipment as per CFO NOC, Electrical fittings, mechanical equipment, compliance to conditions ofenvironment/CRZ NOC, Finishing to entrance lobby/s, plinth protection. paving of areas appurtenant to Building/Wing, Compound Wall and all other requirements as may be required to complete project as per specifications in agreement of Sale.0%
Internal walls, Intemal Plaster, Floorings, Floors and windows within Flats/Premises5%
Internal walls, Internal Plaster, Floorings within Flats/Premises, Doors and Windows to each of the Flat/Premises0%
Plinth100%
Podiums (if any) 66%
Sanitary Fittings within the Flat/Premises,Electrical Fittings within the Flat/Premises0%
Sanitary Fittings within the flats / premises0%
Slabs of Super Structure0%
Staircases, Lifts Wells and Lobbies at each Floor level connecting Staircases and Lifts, Overhead and Underground Water Tanks.22%
Staircases, Lifts Wells and Lobbies at each Floor level Overhead and Underground Water Tanks24%
Stilt Floor0%
The external plumbing and external plaster, elevation, completion of terraces with waterproofing of the Building/Wing0%
X number of Basement(s) and Plinth100%
X number of Podiums11%
X number of Slabs of Super Structure0%

RERA Registered Amenities

Aggregate area of recreational Open Space
Community Buildings
Electrical Meter Room, Sub-Station, Receiving Station
Energy management
Fire Protection And Fire Safety Requirements
Landscaping & Tree Planting
Open Parking
Sewerage (Chamber, Lines, Septic Tank , STP)
Solid Waste Management And Disposal
Storm Water Drains
Street Lighting
Treatment And Disposal Of Sewage And Sullage Water
Water Conservation, Rain water Harvesting
Water Supply
CallWhatsApp
✉️

Get in Touch

Our team will connect with you shortly

+91
🔒 Your details are secure with us
⚡ If need urgent details +91 98200 67525 for further details.
This website is for the use of Actual Home Buyers/Renters and Owners and Property Investors only.